Resumo do Conteúdo

Página 1 - STANDARD

WestinghouseSecurity Electronicsan ISO 9001 certified company5452 Betsy Ross DriveSanta Clara, CA 95054-1184(408) 727-5170FAX (408) 727-6707P/N 661079

Página 2

SECTION 1: INTRODUCTION 1-3Keyholder ID. Keyholder's ID number. The unique ID number is used by the computer to keeptrack of all activity for t

Página 3 - TABLE OF CONTENTS

Section 4: Master File Entry 4-49Read Range. Controls the maximum read range available with the particular digital reader.The range is 0—255; default

Página 4

4-50 Section 4: Master File EntryMAPSThe DRAWMAPS function is used by the event monitoring function to display the location of doors,points, alarms, e

Página 5

Section 4: Master File Entry 4-51ReDraw Redraws screen. Use if graphics appear incorrect.Rectify Makes all lines close to horizontal or vertical exac

Página 6

4-52 Section 4: Master File EntrySE 422 Input Table01234 56ACU (2-state) 0: 1 2 3 4 5 6 7M16 /RO1 1: 8 9 10 11 12 13 14(4-state input) 2: 15 16 17 18

Página 7

SECTION 5MASTER FILE REPORTSINTRODUCTIONThe master file reports list comprehensive database information. The report menu screens areaccessed via the

Página 8 - INTRODUCTION

5-2 SECTION 5: MASTER FILE REPORTSADDITIONAL INFORMATIONAn additional report feature not accessed via the reports menu, 132-xx Column Report Display,i

Página 9 - DEFINITIONS

SECTION 5: MASTER FILE REPORTS 5-306/02/96 BAYOU INDUSTRIES Page 114:45 Key Quick ListKeyholderKey No Keyholder Name Dept. Pos. Phone Title Bldg___

Página 10 - System Hardware — Devices

5-4 SECTION 5: MASTER FILE REPORTSACCESS ASSIGNMENTSKEYHOLDER ACCESS ASSIGNMENTThis report prints the access codes and access groups assigned to keyho

Página 11 - ECTION 1: INTRODUCTION

SECTION 5: MASTER FILE REPORTS 5-5KEYHOLDER ACCESS ASSIGNMENT: EXTENDED — SAMPLE REPORTREADER ACCESS ASSIGNMENTThis report prints keyholder access per

Página 12 - System Software

5-6 SECTION 5: MASTER FILE REPORTSACCESS DEFINITIONACCESS CODE MASTERThis report details all access codes defined in the system (the report can be lim

Página 13 - Principal System Functions

1-4 SECTION 1: INTRODUCTIONReadersDigital Key Reader. Reads the unique number of 1 to 5 digital command keys simultaneouslyat a range of up to 36 inc

Página 14 - SAMPLE SYSTEM

SECTION 5: MASTER FILE REPORTS 5-7ACCESS GROUP MASTER LIST — SAMPLE REPORTACCESS OVERRIDEThe report lists access override codes in the database, with

Página 15 - SE 6000 S

5-8 SECTION 5: MASTER FILE REPORTSINTELLIGENT FAIL SOFT — SAMPLE REPORT03/25/96 Soames Industries Page 108:24 Intelligent Fail Soft ReportKeyholder K

Página 16 - Logging On

SECTION 5: MASTER FILE REPORTS 5-9PROJECT REPORT — SAMPLE REPORT03/25/96 Security Electronics Page 108:29 Project ReportProject Project

Página 17 - Application Screens

5-10 SECTION 5: MASTER FILE REPORTSREADER PROJECT REPORTThe Reader Project Report lists project number, description, readers assigned, current status.

Página 18 - SCREEN EXAMPLES

SECTION 5: MASTER FILE REPORTS 5-11TIME CODES — SAMPLE REPORT03/25/96 Security Electronics Page 108:36 Timecode ReportTmcd Description Start End Mon T

Página 19 - Moving Between Data Fields

5-12 SECTION 5: MASTER FILE REPORTSTENANTS — SAMPLE REPORT05/04/96 TRADE CENTER MAIN Page 109:07 Tenant ReportNumber Description______ ___________1 W

Página 20 - Finding Data

SECTION 5: MASTER FILE REPORTS 5-13SAMPLE INSTRUCTIONS03/25/96 General Electronics Co Page 108:45 Instruction Master ListPoint Point Description Zone

Página 21 - DELETING RECORDS

5-14 SECTION 5: MASTER FILE REPORTSZONES — SAMPLE REPORT03/25/96 Leigh-Haffner Enterprises Page 108:47 Zone ReportZone Description Area Prim Level___

Página 22 - LOGGING OFF

SECTION 5: MASTER FILE REPORTS 5-15DEVICES — SAMPLE REPORTREADERSThis report lists all readers defined in the system. A sample screen follows:03/25/9

Página 23 - Manual Restart

5-16 SECTION 5: MASTER FILE REPORTSREADERS — SAMPLE REPORTPOINTSThis report lists all points defined in the system. A sample screen follows:POINTS —

Página 24 - OPTIONAL FEATURES

SECTION 1: INTRODUCTION 1-5Multiple Switch Monitor (MSM). The MSM is a four-contact switch box that is connected to aWSE ACU and the MSM provides fou

Página 25

SECTION 5: MASTER FILE REPORTS 5-17AUTO OPENS / ACTIVATESThis report lists system points and readers which have auto-open or auto-activate times. A s

Página 26 - ACTIVITY

5-18 SECTION 5: MASTER FILE REPORTS808 DEVICE CONFIGURATIONThis report lists configuration information for the system 800-series ACUs. A sample scree

Página 27 - FUNCTION KEYS

SECTION 5: MASTER FILE REPORTS 5-19 SITE DEFINITION — SAMPLE REPORT03/25/96 Security Electronics Page 109:

Página 28 - Control Devices Function Keys

5-20 SECTION 5: MASTER FILE REPORTSDKR CONFIGURATIONThe reports lists the system default DKR parameters. A sample screen follows:DKR CONFIGURATION —

Página 29 - Control Locks Function Keys

SECTION 5: MASTER FILE REPORTS 5-21SE 422 PIN MASTER REPORT — SAMPLE132-COLUMN REPORT DISPLAYThe local print program was originally written to accommo

Página 30 - Output Points

SECTION 6SYSTEM ADMINISTRATIONINTRODUCTIONThe administration functions are used to control and maintain the system. These functions areaccessed from

Página 31 - Select Zone

6-2 SECTION 6: SYSTEM ADMINISTRATIONADDITIONAL INFORMATIONAdditional system administration-related information is provided at the conclusion of this s

Página 32

SECTION 6: SYSTEM ADMINISTRATION 6-3Program Security Level. Optional (range 1—9999). Code number indicating the specificscreens the user can access.

Página 33 - REAL TIME CONTROL MAPS

6-4 SECTION 6: SYSTEM ADMINISTRATIONJump Timer Servicing. Y / N field indicating if the user has the authority to automaticallyjump to timer servici

Página 34 - Printer Control

SECTION 6: SYSTEM ADMINISTRATION 6-5PROGRAM SECURITY [sec_menu]PROGRAM SECURITY LEVEL ENTRY [pgacentr]Begin creating program security level types by f

Página 35 - Force Table Download

1-6 SECTION 1: INTRODUCTIONResponse Time. The SE 6000 is capable of fast response times in both single and multiple siteconfigurations. Fast respons

Página 36 - Building Modes

6-6 SECTION 6: SYSTEM ADMINISTRATIONEnter Y or N in the add/update/delete fields to give or deny access to these functions on theselected screen. If y

Página 37 - Disk Almost Full Warning

SECTION 6: SYSTEM ADMINISTRATION 6-7DISPLAY ALL VALID LOGINS [showuser]Use the [showuser] screen to identify — by hard copy printout or report display

Página 38

6-8 SECTION 6: SYSTEM ADMINISTRATIONPURGE A PENDING REPORT [purgrprt]Use this feature to halt a report currently being printed (applies only to report

Página 39 - Implementing the Feature

SECTION 6: SYSTEM ADMINISTRATION 6-9EVENTS [evenentr]The task / event subsystem is used to program one or more tasks to be automatically performedin r

Página 40

6-10 SECTION 6: SYSTEM ADMINISTRATIONModifier. Optional. If applicable, the transaction modifier which defines the event if themessage is user-defin

Página 41

SECTION 6: SYSTEM ADMINISTRATION 6-11Activate Code, Extension. Required. System code number for the type of action to beperformed. The extension ap

Página 42 - SECURITY REPORTS

6-12 SECTION 6: SYSTEM ADMINISTRATION100 ACTIVATE PROJECT Activate an inactive project.101 DEACTIVATE PROJECT Deactivate an active project.102 NORMALI

Página 43 - KEYHOLDER HISTORY REPORT

SECTION 6: SYSTEM ADMINISTRATION 6-13Transaction Type (ID). The unique ID number of a transaction. The system is pre-programmed to use specific tran

Página 44 - TRANSACTION HISTORY REPORT

6-14 SECTION 6: SYSTEM ADMINISTRATION2 = Green3 = Cyan (light blue)4 = BlueDisplay Icon. For future use.Printer Group. Each log printer must include

Página 45 - ALARM SERVICING REPORT

SECTION 6: SYSTEM ADMINISTRATION 6-15DATABASE BACKUP. A database backup copies all information in the database (exceptions user and mapinformation).

Página 46 - PASSBACK ZONE REPORT

SECTION 1: INTRODUCTION 1-7Multiple Occupancy Feature. Similar to the two-man rule except that it requires that twokeyholders enter and leave a speci

Página 47 - DOWNLOAD STATUS REPORT

6-16 SECTION 6: SYSTEM ADMINISTRATIONALARM TRANSACTION CLEAN UP [alrmcln]Each time an alarm is triggered, a record is created and stored in a separate

Página 48

SECTION 6: SYSTEM ADMINISTRATION 6-17KEYHOLDER LOADING [loadmenu]This function copies keyholder IDs and names from an DOS ASCII file to a Unix then cr

Página 49 - EVENT / POINT REPORT

6-18 SECTION 6: SYSTEM ADMINISTRATIONID SECURITY GROUP ENTRY [ID2_ entr]This function is used to create ID security groups. A sample screen follows:R

Página 50 - REALTIME PASSBACK ZONE REPORT

SECTION 6: SYSTEM ADMINISTRATION 6-19MISCELLANEOUS INFORMATIONADJUSTABLE BAUD RATE—708P / 800 POLLERSMultiple baud rates are supported for the diverse

Página 51

6-20 SECTION 6: SYSTEM ADMINISTRATIONThis feature is enabled / disabled using the REXEXTEND parameter in the $DATAPATH/NPOLLER.x file where x is the

Página 52 - SECTION 4

SECTION 6: SYSTEM ADMINISTRATION 6-2103/25/96 Ataraxia Electronics Page 115:52 Inventory Status Code ReportCode Code Description____ ________________1

Página 53 - KEYHOLDERS

6-22 SECTION 6: SYSTEM ADMINISTRATION03/25/96 Alpha Systems Page 115:55 Key Inventory ReportKeyholder Keyholder Name Key No Date Time Status Descrip

Página 54

SECTION 6: SYSTEM ADMINISTRATION 6-23PARKING STICKER MASTER REPORT [stkrprt]The report lists assigned parking stickers. A sample screen and report fo

Página 55 - ECTION 4: MASTER FILE ENTRY

APPENDIX A: SYSTEM SCREEN TREES A-1monitorctrlpollctrllockctrlprntctrlinpctrldoorselzonectrloutctrldevdevstatviewmapinsrtnsresponsedownloadpsbkfrgvman

Página 56

A-2 APPENDIX A: SYSTEM SCREEN TREESacrtrprtalmarprtwhowhereexcprprtphstrprtchstrprtaccsmenumainmenuky2nrprtevptrprtrpasrprtdownrprtScreen Location Tre

Página 57 - Project Assignment [epj_entr]

1-8 SECTION 1: INTRODUCTIONCREATING THE DATABASEOnce the system is in place, first obtain the following from the system installer:System Interconnect

Página 58 - COPY KEYHOLDERS

APPENDIX A: SYSTEM SCREEN TREES A-3empgentregrpentr1key_entrtmcdentrhol_entrtententrpol_entrd422entrzoneentrdev_entrrdr1entrrdr_entrdialentrabacentrd8

Página 59 - ACCESS ASSIGNMENT

A-4 APPENDIX A: SYSTEM SCREEN TREESrprtmenuhol_rprtkey_rprtdeptrprtjob_rprtmaprprtinstrprtpol_rprtzonerprtdev_rprtrdr_rprtpnt_rprt autorprtmainmenuacc

Página 60 - ACCESS CODE ENTRY [acdsentr]

APPENDIX A: SYSTEM SCREEN TREES A-5Screen Location Tree — Key Inventoryinvtmenustatentrcdinrptstatmenustatrprtcdientrmainmenustkrentrstkrprtstkrprt1st

Página 61

A-6 APPENDIX A: SYSTEM SCREEN TREESloadmenupurgrprtpgacrprtshowwhosec_menusyclmenuaccsarchbeepentrmnaccopypgacentrevenentrtranentrdb_menushowusermod_p

Página 62 - LEVATOR DEFINITION [eleventr]

APPENDIX B: SYSTEM SCREEN HIERARCHIES B-1MONITOR SECURITY ACTIVITYSCREEN TITLE FUNCTIONmonitor Watch events and activities as they occur; menu to othe

Página 63

B-2 APPENDIX B: SYSTEM SCREEN HIERARCHIESkey_copy Create new keyholder record by copying from an existing keyholder record.egrpentr Select a keyholder

Página 64 - ACCESS OVERRIDE ENTRY

APPENDIX B: SYSTEM SCREEN HIERARCHIES B-3MASTER FILE REPORTSSCREEN TITLE FUNCTIONrprtmenu Menu to database reporting functions.key_rprt Report keyhold

Página 65 - FAILSOFT ENTRY

B-4 APPENDIX B: SYSTEM SCREEN HIERARCHIESPARKING STICKERSSCREEN TITLE FUNCTIONstkrmenu Menu to parking sticker and license plate management functions.

Página 66

# Message ExplanationAPPENDIX C: SYSTEM TRANSACTIONS — NUMERICAL SEQUENCE C-10 Negative Acknowledge 708P unable to understand message from host.1 Acce

Página 67 - HOLIDAYS [hol_entr]

# Message ExplanationC-2 APPENDIX C: SYSTEM TRANSACTIONS — NUMERICAL SEQUENCE29 Printer On Log printer switched on.30 Device Reset 708P / 8xx-series p

Página 68 - INSTRUCTIONS [instentr]

SECTION 1: INTRODUCTION 1-91. Following the System Interconnect Diagram, number each element in turn with a four-digitnumber, including numbers for de

Página 69 - ZONES [ZONEENTR]

# Message ExplanationAPPENDIX C: SYSTEM TRANSACTIONS — NUMERICAL SEQUENCE C-354 Device Online ACU communicating with host.55 Request Manual Access Man

Página 70 - POLLERS [pol_entr]

# Message ExplanationC-4 APPENDIX C: SYSTEM TRANSACTIONS — NUMERICAL SEQUENCE83 Enter Unattended Mode Optional parking function.84 Batch Request Recei

Página 71

# Message ExplanationAPPENDIX C: SYSTEM TRANSACTIONS — NUMERICAL SEQUENCE C-5115 Power Report Unshunted Device power fail report unshunted.116 COAX Re

Página 72

# Message ExplanationC-6 APPENDIX C: SYSTEM TRANSACTIONS — NUMERICAL SEQUENCE142 Host Dial Start Remote device dialing host.143 Carrier Off SE 422—Inc

Página 73 - [dev_entr] — ALL DEVICE TYPES

# Message ExplanationAPPENDIX C: SYSTEM TRANSACTIONS — NUMERICAL SEQUENCE C-7178 VIP Failure VIP keypad not responding.179 VIP Okay VIP keypad returne

Página 74

# Message ExplanationC-8 APPENDIX C: SYSTEM TRANSACTIONS — NUMERICAL SEQUENCE242 Disk Almost Full Disk space at value of DISKWARN parameter (usually 9

Página 75

Message #Message #APPENDIX C: SYSTEM TRANSACTIONS — ALPHABETICAL SEQUENCE C-9ABA Card Data 1 ... 173ABA Card Dat

Página 76

Message #Message #C-10 APPENDIX C: SYSTEM TRANSACTIONS — ALPHABETICAL SEQUENCEMax Tenant In Lot ... 80Meal Count

Página 77

APPENDIX D: PROGRAM SECURITY MASTER LIST D-1Level 1 = COMPLETE SYSTEM ACCESSID1_entr ID Security User Entry Y Y YID1_rprt ID Security Report N N NID2_

Página 78

D-2 APPENDIX D: PROGRAM SECURITY MASTER LISToutsrprt Outstanding Tickets N N Noverrprt Tenant Overage N N Np422rprt SE/422 PIN Report N N Npadmmenu Pa

Página 79

1-10 SECTION 1: INTRODUCTIONSystem ScreensThere are two basic screen types: Menu and Application:Menu ScreensMenu screens list application selections

Página 80

INDEX-1INDEXAAccess Assignment, 4-8, 5-4Keyholder Access, 5-4Keyholder Access Assignment, 4-8Readers, 5-5Access Code, 1-2Access Code Entry, 4-9D

Página 81

INDEX-2Auto Opens/Activates, 4-42Automatic Access Control, 1-6Automatic Activate / Deactivate, 1-6Automatic Restart, 1-16Automatic Unlock/Lock, 1

Página 82

INDEX-3DData Entry Sequence, 1-9Data Item Selection, 2-2Database Changes, 1-7Database Maintenance [db_menu], 6-14Definition, GeneralTrace, 1-3Tra

Página 83 - READER ENTRY [rdr_entr]

INDEX-4Definitions, Principal System Functions, 1-6Auto Activate/Deactivate, 1-6Automatic Access Control, 1-6Communications Monitor, 1-6Flexible E

Página 84

INDEX-5NexSentry Reader Report Defined, 4-38Reader Entry, 4-32Reader Report, 4-35Readers, 4-31Devices Configuration ReportsDevices, 5-14Readers,

Página 85 - MULTIPLE OCCUPANCY READER

INDEX-6Forgive Passback, 2-10Full Screen Monitoring, 2-12Function Keys, 2-2GGeneral DefinitionsKeyholder, 1-2Guard Tour, 1-18HHardware Configuati

Página 86

INDEX-7JJob Category, 1-2Journal Archive [jourarch], 6-16Journal Reporting [jourrprt], 6-16KKey Inventory [invtmenu], 6-20Key Inventory Entry [cdi

Página 87

INDEX-8MicroprocessorAccess Control Units, 1-3Biometric Hand Reader, 1-3Miscellaneous Information, 1-15, 2-12Modified Usage of Invalid Facility Cod

Página 88

INDEX-9Program Security Entry Definition [pg1_entr], 6-5Purge a Pending Report [purgrprt], 6-8RReader Entry, 4-32Reader Report, 4-35818, 4-37NexS

Página 89

INDEX-10Review TransactionsFull Screen, 2-7Review Transactions Function Keys, 2-8REX, 1-5SSample System, 1-7Screen Access, 4-1Screen Examples, 1

Página 90 - POINTS [pnt_entr]

SECTION 1: INTRODUCTION 1-11Indicates replace or insert mode. With replace, entries overwrite existing data. With insert,entries push existing data

Página 91

INDEX-11Tenant, 1-3Tenants, 4-17, 5-11Time and Attendance, 1-18Time Code, 1-3Time Codes, 4-16, 5-10Trace, 1-3Transaction History Report, 3-3Sam

Página 92

1-12 SECTION 1: INTRODUCTIONUSING SCREENS AND FIELDSSelecting ScreensThere are three screen selection methods:1. Use the arrow keys to select the menu

Página 93

LIMITED WARRANTYWestinghouse Security Electronics (WSE) warrants to the original user the equipment manufactured by WSE asdescribed herein (the equipm

Página 94 - SE 422 PIN DEFINITION

SECTION 1: INTRODUCTION 1-13Moving to Prior ScreensPress F1 to return to the previous screen displayed. If required, continue to press F1 to returnt

Página 95 - SE 422 HARDWARE DEFINITION

1-14 SECTION 1: INTRODUCTIONThe computer automatically changes to the update mode when a search completes, and therecords selected can be updated if r

Página 96 - DIALER ENTRY

SECTION 1: INTRODUCTION 1-15ZOOM FEATUREThe zoom feature provides a fast method for accessing linked or dependent application screensand for copying d

Página 97 - SITE ENTRY DEFINITION

1-16 SECTION 1: INTRODUCTIONIMPORTANTLog off the SE 6000 system formally before you leave the terminal. If you do not log off, any actiontaken by the

Página 98 - ABA CONFIGURATION ENTRY

SECTION 1: INTRODUCTION 1-173. The computer displays Enter new time ([yymmdd]hhmm). Change the date and time valuesas required (do not enter the pare

Página 99 - DKR CONFIGURATION ENTRY

1-18 SECTION 1: INTRODUCTIONController Systems. Controller systems are computers running the SE 6000 local (LC) or remotelocation controller (RLC) so

Página 100 - USER-DEFINED INFORMATION

SECTION 2: MONITOR SECURITY ACTIVITY 2-1SECTION 2MONITOR SECURITYACTIVITYINTRODUCTIONSystem monitoring and control is performed via the monitor menu,

Página 101 - COMMAND DESCRIPTION

2-2 SECTION 2: MONITOR SECURITY ACTIVITYFUNCTION KEYSBeneath the transactions display are the applicable function keys for each screen, with the keyac

Página 102

SECTION 2: MONITOR SECURITY ACTIVITY 2-3When F4 is pressed, a second screen displays showing the connections between the host andthe devices of the pa

Página 103

2-4 SECTION 2: MONITOR SECURITY ACTIVITYF4 KEY RSET. Key Reset—Used when setting up new ACUs or reestablishing repaired ACUs,or when the integrity of

Página 104 - MASTER FILE REPORTS

iiiTABLE OF CONTENTSSECTION 1: INTRODUCTION ... 1-1MANUAL ORGANIZATION ...

Página 105 - KEYS MASTER

SECTION 2: MONITOR SECURITY ACTIVITY 2-5F6 UNSHUNT. Unshunt a door previously shunted.Input PointsThe Control Inputs screen displays point ID, descri

Página 106

2-6 SECTION 2: MONITOR SECURITY ACTIVITYF6 UNSHUNT. Unshunt a selected output point previously shunted. If no output point is selected,F6 unshunts a

Página 107 - ACCESS ASSIGNMENTS

SECTION 2: MONITOR SECURITY ACTIVITY 2-7Count — Number of keyholders currently in the zone.PBarea — Passback zone type—personal, vehicle, none.PBtype

Página 108 - READER ACCESS ASSIGNMENT

2-8 SECTION 2: MONITOR SECURITY ACTIVITYReview Transactions Function KeysF2 BACKWARD. Page backward through the transactions.F3 FORWARD. Page forwar

Página 109 - ACCESS DEFINITION

SECTION 2: MONITOR SECURITY ACTIVITY 2-9CONTROL PROJECTSThe Control Projects screen (not controllable on LC systems—host only) displays project, statu

Página 110 - INTELLIGENT FAIL SOFT REPORT

2-10 SECTION 2: MONITOR SECURITY ACTIVITYF5 PRNT ON. Switch printer #1 on or off depending on current state (used to control log printeronly).F6 PRNT

Página 111 - PROJECT REPORT

SECTION 2: MONITOR SECURITY ACTIVITY 2-11When requested, enter the number of the table to be downloaded and press Enter. The systemrequests confirmat

Página 112 - KEYHOLDER PROJECT REPORT

2-12 SECTION 2: MONITOR SECURITY ACTIVITYF3 LIMITED. Change current building mode to limited.F4 CLOSED. Change current building mode to closed (take

Página 113 - TIME CODES

SECTION 2: MONITOR SECURITY ACTIVITY 2-13Status Screen Function TimeoutSome system functions temporarily disable the realtime display until the sub-me

Página 114 - HOLIDAYS

2-14 SECTION 2: MONITOR SECURITY ACTIVITYNOTE1. The control parameter is read by the alarm servicing program at log-on time and remains ineffect as lo

Página 115 - INSTRUCTIONS

ivDoors ... 2-6Select Zone ...

Página 116 - DEVICE CONFIGURATION REPORTS

SECTION 2: MONITOR SECURITY ACTIVITY 2-15NOTE1. If your system has been upgraded, and users created on a previous release have beensaved, their user p

Página 117 - POLLERS — SAMPLE REPORT

2-16 SECTION 2: MONITOR SECURITY ACTIVITY1. This feature affects the following displays and reports:- Monitor screen, both full- and half-screen displ

Página 118 - DEVICES — SAMPLE REPORT

SECTION 3SECURITY REPORTSINTRODUCTIONSecurity management reports provide a permanent record of transactions, and are also used toexamine specific even

Página 119 - POINTS — SAMPLE REPORT

3-2 SECTION 3: SECURITY MANAGEMENTS REPORTSNOTE1. Some reports are over-wide (132 characters instead of the standard 80 characters), andhave been form

Página 120 - 808 REPORT DEFINITION

SECTION 3: SECURITY MANAGEMENT REPORTS 3-3Keyholder History — Sample Report06/27/96 Packlett Industries PAGE 114:36 Point HistoryPoint Point Descri

Página 121 - SITE DEFINITION

3-4 SECTION 3: SECURITY MANAGEMENTS REPORTSTransaction History — Sample ReportACCESS CONTROL ARCHIVE REPORTThe access control archive report, [acrtrpr

Página 122 - ABA CONFIGURATION

SECTION 3: SECURITY MANAGEMENT REPORTS 3-5Alarm Servicing — Sample ReportPASSBACK ZONE REPORTThe passback zone report, [whowhere], lists keyholders cu

Página 123 - SE 422 PIN MASTER REPORT

3-6 SECTION 3: SECURITY MANAGEMENTS REPORTSPassback Zone — Sample Report04/05/96 Easthaven Manufacturing Page 114:43 Passback Zone ReportKeyholder Ke

Página 124 - 132-COLUMN REPORT DISPLAY

SECTION 3: SECURITY MANAGEMENT REPORTS 3-7Possible system messages for this report are:Unprocessed — Information changed in the database, but

Página 125 - SYSTEM ADMINISTRATION

3-8 SECTION 3: SECURITY MANAGEMENTS REPORTSKEYHOLDER ZONE REPORTThe report lists the most recent zone information for all keyholders that meet the sea

Página 126 - ADD USERS [addusers]

vKeyholder Access Entry [empgentr] ... 4-5Project Assignment [epj_entr] ...

Página 127 - MPORTANT

SECTION 3: SECURITY MANAGEMENT REPORTS 3-9Event / Point — Sample Report03/17/96 Security Electronics Page 109:15 Event/Point ReportPoint Point Descr

Página 128 - MODIFY PASSWORDS [mod_pass]

3-10 SECTION 3: SECURITY MANAGEMENTS REPORTSREALTIME PASSBACK DETAIL — SAMPLE REPORT03/14/96 McPowell-Angus Aviation Page 115:18 Realtime Passback Det

Página 129 - PROGRAM SECURITY [sec_menu]

SECTION 4: MASTER FILE ENTRY 4-1SECTION 4MASTER FILE ENTRYINTRODUCTIONThe master file entry procedures are used to create and maintain the database.

Página 130 - COPY SECURITY [mnaccopy]

4-2 SECTION 4: MASTER FILE ENTRYKEYHOLDERSFour data entry screens are used to add new keyholders to the system, and to change or deleteexisting keyhol

Página 131 - [showwho]

SECTION 4: MASTER FILE ENTRY 4-3Keyholder ID. Required in the Add mode (the system denies further screen access until thisfield is entered). Enter a

Página 132 - (syclmenu)

4-4 SECTION 4: MASTER FILE ENTRYIssue Date. Optional. Enter the date that the access control card for the keyholder willbecome valid. Default is cu

Página 133 - EVENTS [evenentr]

SECTION 4: MASTER FILE ENTRY 4-5Keyholder Access Entry [empgentr]Access Code. Optional. Enter an access code number that applies to this keyholder (

Página 134 - TASKS [taskentr]

4-6 SECTION 4: MASTER FILE ENTRYY if the downloaded access code is to be sent to the ACU as a smart failsoft access code.Default is N. Note that this

Página 135 - CTIVATE / DEACTIVATE CODES

SECTION 4: MASTER FILE ENTRY 4-7A sample [epj_entr] screen follows. Enter the project number (zoom available) then press Enter;the project descriptio

Página 136 - TRANSACTIONS [tranentr]

4-8 SECTION 4: MASTER FILE ENTRYACCESS ASSIGNMENTKeyholder Access Assignment [egrpentr]The [egrpentr] and [egrpentr1] screens, accessed from Access As

Página 137

viReader Access Assignment ... 5-5Reader Assignment — Sample Report ...

Página 138 - PERFORM BACKUP [bkup]

SECTION 4: MASTER FILE ENTRY 4-9ACCESS DEFINITIONThe access definition selection in the master file entry menu displays the access definition menu:• A

Página 139

4-10 SECTION 4: MASTER FILE ENTRYAccess Code ID. Required. Enter a four-digit maximum access code number.Tenant. Required (zoom available). Enter

Página 140 - JOURNAL REPORTING [jourrprt]

SECTION 4: MASTER FILE ENTRY 4-11Reader ID. Required. Enter the reader number to be linked to this access code (the readerdescription is automatical

Página 141 - KEYHOLDER LOADING [loadmenu]

4-12 SECTION 4: MASTER FILE ENTRYGroup Description. Required. Enter a 30-character maximum description of the accessgroup.When screen entry is compl

Página 142 - ECURITY REPORT [ID1_ rprt]

SECTION 4: MASTER FILE ENTRY 4-13WARNING1. Access codes that include the same reader(s) should not be included in the same groupunless one code is a d

Página 143 - MISCELLANEOUS INFORMATION

4-14 SECTION 4: MASTER FILE ENTRYFAILSOFT ENTRY708P ACUs can be programmed to recognize up to 25 keyholders (based on key numbers) foruse when communi

Página 144 - KEY INVENTORY [invtmenu]

SECTION 4: MASTER FILE ENTRY 4-15Project ID. Required. Enter a four-character maximum project ID code.Description. Optional. Enter a 40-character

Página 145 - EY INVENTORY ENTRY [cdinentr]

4-16 SECTION 4: MASTER FILE ENTRYTIME CODES [tmcdentr]Time codes are normally used to define when points and readers are active. The codes are alsous

Página 146 - PARKING STICKERS [stkrmenu]

SECTION 4: MASTER FILE ENTRY 4-17Holiday Name. Optional. Enter a 20-character maximum holiday name.TENANTS [tententr]Two or more companies or groups c

Página 147

4-18 SECTION 4: MASTER FILE ENTRYPoint ID. Required (zoom available). Enter the point ID to which this instruction applies.Tenant. The tenant numbe

Página 148 - (Full Screen)

viiSECTION 6: SYSTEM ADMINISTRATION ... 6-1INTRODUCTION ...

Página 149

SECTION 4: MASTER FILE ENTRY 4-19Passback Area. Optional. This field is used to indicate if passback is in effect for this zone.Enter P if personnel

Página 150

4-20 SECTION 4: MASTER FILE ENTRYThe SE 6000 can run different pollers or multiple copies of the same poller concurrently but, withthe exception of th

Página 151

SECTION 4: MASTER FILE ENTRY 4-21Tenant. Optional (zoom available). Enter a four-digit maximum tenant code number.Default is 0.Computer ID. Requir

Página 152

4-22 SECTION 4: MASTER FILE ENTRYcontrolled exclusively by the SE 6000 (deferred mode), to operate entirely independently of theSE 6000 (local mode),

Página 153 - Security

SECTION 4: MASTER FILE ENTRY 4-23Address. Required. Enter the address of the device. Since each poller can poll a numberof devices, the Address fi

Página 154 - MASTER FILE ENTRY

4-24 SECTION 4: MASTER FILE ENTRYSE 8XX-SERIES DEVICE CONFIGURATION ENTRY [d808entr]The [d808entr] screen must be completed for all 8xx-series ACUs (u

Página 155

SECTION 4: MASTER FILE ENTRY 4-25Power Fail. Optional. Enter the power fail report number if a report has been created (seeapplicable ACU manual). T

Página 156 - KEY INVENTORY

4-26 SECTION 4: MASTER FILE ENTRYBuilding Closed Time Codes. Optional. Provides up to four time intervals during which thebuilding should be close

Página 157 - PARKING STICKERS

SECTION 4: MASTER FILE ENTRY 4-27NOTEThe Level, Name and Password fields are specific to the NexSentry and applies only tooperators logging in directl

Página 158

4-28 SECTION 4: MASTER FILE ENTRYSE 818 DEVICE CONFIGURATION ENTRY [d818entr]Complete the [d818entr] screen for all 818-series and NexSentry ACUs (use

Página 159

SECTION 1: INTRODUCTION 1-1SECTION 1INTRODUCTIONMANUAL ORGANIZATIONThis manual follows the order of the seven standard product items in the system mai

Página 160

SECTION 4: MASTER FILE ENTRY 4-29Level, Name, Password. Required. These first three fields are entered to identify up to eightoperators who will be

Página 161

4-30 SECTION 4: MASTER FILE ENTRYPIN Timeout. Optional. The maximum amount of time, in seconds, which can pass betweenthe presentation of a key and

Página 162

SECTION 4: MASTER FILE ENTRY 4-31Duress Enable. Indicates with a Y or an N whether the PIN duress feature of the SE 422is turned on or not.Show P

Página 163

4-32 SECTION 4: MASTER FILE ENTRYREADER ENTRY [rdr_entr]Reader ID. Required (zoom available). Enter a maximum four-digit reader ID number.Reader Des

Página 164

SECTION 4: MASTER FILE ENTRY 4-33Reader Type. Required. Enter the reader type number in the ranges 1 through 12 asdescribed above.Assoc Reader ID

Página 165

4-34 SECTION 4: MASTER FILE ENTRYactive. For Mod, enter a transaction modifier code (A, B, etc.) to customize log messagesand system actions (see Sec

Página 166

SECTION 4: MASTER FILE ENTRY 4-35configured for a specific zone and includes the passback feature. In addition, the MOR and theSE 6000 keep track of t

Página 167

4-36 SECTION 4: MASTER FILE ENTRYin response to various events occurring within the system. (The field titles indicate the eventtypes.) See Device R

Página 168

SECTION 4: MASTER FILE ENTRY 4-37 —The following ten fields, Forced Open through Exit Granted, require the entry of a report number.The word repo

Página 169

4-38 SECTION 4: MASTER FILE ENTRYProximity Type. Enter the proximity type: 0 = Sensor interface, 1 = DigiKey reader.The following thirteen fields, DKR

Página 170

1-2 SECTION 1: INTRODUCTIONDocumentation MethodsTo avoid repetition and to reduce document size, detailed explanations for the system's principal

Página 171

SECTION 4: MASTER FILE ENTRY 4-39The following eleven fields, DKR/SCR Fail through Device Tamper, require the entry of areport number. The report in t

Página 172

4-40 Section 4: Master File EntryPoint ID. Required. Enter a four-digit maximum point ID number.Point Description. Optional. Enter a 20-character

Página 173

Section 4: Master File Entry 4-41Time. Required for point type 2 (door switch) and 6 (general, when used with an OPTO 22);disregard for all other ty

Página 174

4-42 Section 4: Master File EntryZone number. Required (zoom available). Enter the zone number applicable for this point.The system enters the def

Página 175

Section 4: Master File Entry 4-43Serial #. A nine-digit maximum control number automatically generated and displayed bythe system when a new auto ope

Página 176

4-44 Section 4: Master File EntryAssigned PIN numbers can be printed out (see Section 3, SE 422 PIN Master Report). Also, itis possible, but not reco

Página 177

Section 4: Master File Entry 4-45Dev Failure Rpt. Optional. Enter a device failure report number in the range 1 — 32. Defaultis 0 — No report.Ser

Página 178

4-46 Section 4: Master File EntryHost2. Required, if applicable. Enter alternate host #2 phone number. For RDI units only,enter login string and p

Página 179

Section 4: Master File Entry 4-47Group ID. Enter a four-character maximum group ID number.Code. Enter a four-character maximum site code. Enter x i

Página 180

4-48 Section 4: Master File EntryKey B. Start position and length of second part of key.Key C. Start position and length of third part of key.Expi